Causes of spontaneous combustion of distribution transformers

One, There is no insurance on both sides of the distribution transformer high and low voltage. Although some have been equipped with drop fuses and horn safety, the fuses are mostly replaced by aluminum or copper wire, so that when the low voltage is short-circuited or overloaded, the fuse cannot be blown normally and the transformer is burnt. The high and low fuses of the distribution transformer are not properly configured. The fuse on the transformer is generally over-configured, causing the dry distribution transformer to burn out the transformer when it is heavily overloaded.
Second, due to the large number of rural lighting lines, most of them use single-phase power supply, coupled with the randomness and management of the jumper during construction, resulting in the partial phase operation of the distribution transformer load. For long-term use, the insulation of a phase coil is aging, causing the transformer to burn out.
distribution transformers,dry distribution transformer,oil-immersed distribution transformer
Third, the tap changer.
1. Adjust the tap changer privately. Due to the large difference in power load between winter and summer, the voltage changes greatly. Therefore, some rural and enterprise electricians adjust the tap changer without the test adjustment of the power repair department, causing the distribution switch to be out of position, and the contact is poor and burned.
2. The quality of the tap-changer is poor, the structure is unreasonable, the pressure is not enough, the contact is unreliable, the position of the external character wheel is not completely consistent with the actual internal position, causing the position of the star-shaped moving contact to be incomplete contact, and the misaligned moving and static contacts make The insulation distance between the two taps becomes small, and a short circuit or a discharge to the ground occurs under the potential between the two taps, and the short-circuit current will quickly burn the tap wire and even cause the entire winding to be damaged.
Fourth, oil seepage is the most common abnormal appearance of transformers. Since the oil-immersed distribution transformer is filled with oil, there are rubber beads and rubber pads at each joint to prevent oil leakage. After a long period of operation, some rubber beads and rubber pads in the transformer will be cracked and cause oil leakage, which will lead to performance degradation after insulation and moisture, short circuit and burned transformer.
Fifth. Most of the high and low voltage lines of the distribution transformer are introduced by overhead lines. Since the 10kV arrester is not installed, the transformer will be burned when lightning strikes.

For safety, use a high quality ZTELEC distribution transformer.