Any Questions? Call Us: :+8613137718313

Temperature Requirements and Application Analysis of Dry-Type Transformers

Images
Temperature Requirements and Application Analysis of Dry-Type Transformers
  • By ZTELEC GROUP
  • 2025-02-26

As an indispensable component of modern power systems, dry-type transformers are widely utilized in high-rise buildings, subways, airports, hospitals, and other settings with stringent safety requirements due to their oil-free, fire-resistant, and environmentally friendly characteristics. Compared to oil-immersed transformers, dry-type transformers impose stricter temperature requirements during operation, as temperature control directly impacts their performance, lifespan, and safety.

 Dry-Type Transformers

Temperature Requirements for Dry-Type Transformers

1. Impact of Temperature on Dry-Type Transformers

The core material of dry-type transformers is insulation, which is highly sensitive to temperature fluctuations. Excessively high operating temperatures can accelerate the aging of insulation materials, degrade their insulating properties, and potentially lead to equipment failure or even fire hazards. Furthermore, elevated temperatures increase thermal stress within the transformer, which may result in winding deformation or mechanical damage. Consequently, temperature control is a critical factor in the design and operation of dry-type transformers.

2. Temperature Rise Limits for Dry-Type Transformers

According to the International Electrotechnical Commission (IEC) standards, the temperature rise limits for dry-type transformers are categorized based on insulation classes:

- Class A Insulation: Maximum allowable temperature rise of 60K, suitable for general environments.

- Class E Insulation: Maximum allowable temperature rise of 75K, suitable for moderately high-temperature environments.

- Class B Insulation: Maximum allowable temperature rise of 80K, suitable for high-temperature environments.

- Class F Insulation: Maximum allowable temperature rise of 100K, suitable for high-temperature and high-humidity environments.

- Class H Insulation: Maximum allowable temperature rise of 125K, suitable for extreme high-temperature environments.

These temperature rise limits are based on an ambient temperature of 40°C. In practical applications, the operating temperature of dry-type transformers must be strictly maintained within the permissible range to ensure long-term stability and reliability.

3. Cooling Methods for Dry-Type Transformers

Dry-type transformers primarily employ two cooling methods:

- Natural Air Cooling (AN): Relies on natural convection for heat dissipation, suitable for small-capacity transformers.

- Forced Air Cooling (AF): Uses fans to enhance airflow, improving heat dissipation efficiency, and is ideal for large-capacity transformers.

Selecting an appropriate cooling method is essential for maintaining optimal operating temperatures and extending the transformer's service life.

 Dry-Type Transformers

Temperature Monitoring and Control of Dry-Type Transformers

1. Temperature Monitoring Systems

Modern dry-type transformers are typically equipped with advanced temperature monitoring systems to ensure real-time oversight of operating conditions. Common monitoring devices include:

- PT100 Temperature Sensors: Installed on windings and cores to provide real-time temperature data.

- Smart Temperature Controllers: Offer temperature alarms and fault diagnostics through data collection and analysis.

These systems enable the early detection of temperature anomalies, preventing overheating and potential equipment damage.

2. Temperature Control Measures

To maintain the operating temperature within safe limits, the following measures can be implemented:

- Optimized Heat Dissipation Design: Enhance cooling efficiency through improved transformer structural design.

- Regular Maintenance: Clean transformer surfaces to remove dust and debris, ensuring unobstructed heat dissipation pathways.

- Environmental Control: In high-temperature settings, install ventilation or air conditioning systems to lower ambient temperatures.

Temperature Management of Dry-Type Transformers in Practical Applications

1. Application in High-Rise Buildings

In high-rise buildings, dry-type transformers are often installed in confined spaces such as distribution rooms or basements, where heat dissipation is challenging. Implementing forced air cooling and temperature monitoring systems ensures effective temperature control, safeguarding power supply reliability.

2. Application in Subways and Tunnels

In subways and tunnels, dry-type transformers operate in high-humidity and high-temperature environments. Utilizing F-class or H-class insulation materials, combined with forced air cooling systems, ensures stable performance under these demanding conditions.

3. Application in Industrial Plants

In industrial settings, dry-type transformers frequently operate at full load for extended periods, necessitating rigorous temperature management. Optimizing heat dissipation designs and conducting regular maintenance are crucial for ensuring reliability in high-temperature environments.

The temperature requirements of dry-type transformers are a cornerstone of their design and operation. By carefully selecting insulation classes, optimizing cooling methods, integrating temperature monitoring systems, and implementing effective control measures, the stable operation of dry-type transformers across diverse environments can be ensured. In practical applications, efficient temperature management not only extends the lifespan of the equipment but also enhances the overall safety and reliability of power systems. Looking ahead, advancements in materials science and intelligent monitoring technologies promise even more precise temperature control, further expanding the applications of dry-type transformers.

 

Prev:Application of American Box-type Substation Pad Mounted Transformer Substation

Next:A Comprehensive Analysis of Dry-Type Transformer Fault Types